Find Vacuum Circuit Breaker , Vacuum Circuit Breaker, Indoor High Voltage Vacuum Circuit Breaker on Industry Directory, Reliable Manufacturer/Supplier/Factory from China.

Inquiry Basket (0)
Home > Products > 24kv-Vacuum Circuit Breaker > Vs1 Indoor Hv Vcb with Common Insulated Cylinder

Vs1 Indoor Hv Vcb with Common Insulated Cylinder

Basic Info

Model No.:  VS1-24

Product Description

Model NO.: VS1-24 Operation: Energy-storage Type Arc-extinguishing Medium: Vacuum Structure: ACB Type: Circuit Breaker Certification: VDE, ISO9001-2000, CE, CB, CCC Industry Standard: IEC Volume: Small Trademark: Longxiang Electric Origin: Baoji Shaanxi China Breaking Capacity: High Voltage Circuit Breakers Speed: Normal Type Circuit Breaker Installation: Withdrawable Poles Number: 3 Function: Conventional Circuit Breaker Rated Voltage: 24kv The Capability Grade: M2-E2-C2 Design: Compact Specification: IEC: M2-E2-C2 HS Code: 85389000 VS1-24
Indoor High Voltage Vacuum Circuit Breaker with Common Insulated Cylinder
 
General Description
VIB-24 series of Indoor High Voltage Vacuum Circuit Breaker with Common Insulated Cylinder is three-phase A.C.50Hz indoor power distribution equipment with the rated voltage of 24KV.It's used for protecting and controlling the electrical equipment in the fileds of industry & minning enterprise,power plants and Substation.This type Vacuum Circuit Breaker conforms to national standards and the stipulation of IEC standard,the capability reaches grade of M2-E2-C2.
The product adopt composite insulation way,spring charged operation and screw rod push mechanism, with the characeristics of small volume,compact design and reliable operation, it can easily match with the Switchgear and meet the "Five Preventions"demands.
This kind of Vacuum Circuit Breaker can be used for many kinds of switchgear like KYN28-24(GZS1),This series of products include:VCB truck,isolation truck and fuse truck etc.

Applying ambient conditions
1.Ambient temperature:-15ºC~+40ºC.
2.Ambient humidity:the average humidity of a day should be no more than 95%;the average humidity of a month should be no more than 90%.
3.Earthquake intensity:not exceed 8 degrees.
4.Saturated vapour pressure:the average pressure of a day should be no more than 2.2kPa;the average pressure of a month should be no more than 1.8kPa.
5.The height above sea level:1000m(besides the special requirements).
6.It should be installed in the places without fire,explosion,serious filth,chemical erosion and violent vibration.

Main technical specification
S.N Name Unit                                          Data
1 Rated voltage kV                                            24
2 Rated current A 630 1250 1600 2000 2500 3150
3 Rated frequency Hz 50
4 Rated short circuit breaking current kA 20 25 31.5
5 Rated short circuit making current kA 50 63 80
6 Rated short time withstand current kA 20 25 31.5
7 Rated peak withstand current kA 50 63 80
8 Rated power frequency withstand voltage kV 65
9 Rated lightning impulse withstand voltage kV 125
10 Rated short-circuit duration s 4
11 Rated operating sequence
O-0.3s-CO-180s-CO
12 DC component
50%
13 Mechanical endurance Cycle 10000

Overall outline drawing
Vs1 Indoor Hv Vcb with Common Insulated Cylinder
Vs1 Indoor Hv Vcb with Common Insulated Cylinder
Following information is required for order
VCB Full type,main technical specification,distance between phase and quantity.
Type and specification of service voltage.
Name and quantity of spare parts.

Typical wiring diagram of the second principle
Vs1 Indoor Hv Vcb with Common Insulated Cylinder
If you have any question,pls feel free contact us.

Contact us if you need more details on Vs1-24. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Vs1、24kv Vacuum Circuit Breaker. If these products fail to match your need, please contact us and we would like to provide relevant information.

Product Categories : 24kv-Vacuum Circuit Breaker