Model No.: ZN39-40.5
Product Description
Model NO.: ZN39-40.5 Operation: Energy-storage Type Arc-extinguishing Medium: Vacuum Structure: MCCB Type: Circuit Breaker Certification: VDE, ISO9001-2000, CE, CB, CCC Rated Current: 1250/1600/2000A Closing Time: 30~100ms Trademark: Longxiang Electric Origin: China Baoji Breaking Capacity: High Voltage Circuit Breakers Speed: Normal Type Circuit Breaker Installation: Withdrawable Poles Number: 3 Function: Conventional Circuit Breaker Rated Voltage: 40.5kv Rated Frequency: 50Hz Rated Short-Circuit Duration: 4s Specification: IEC: M2-E2-C2 HS Code: 85389000 ZN39-40.5
Truck Type Indoor High-voltage Vacuum Circuit Breaker
General Description
ZN39-40.5 type indoor HV vacuum breaker is used for many kinds of Switchgear like JYN1-35 and GBC-35.It is widely used for 40.5kV voltage systems is accordance with GB1984-2003 standards.
This series include:Vacuum circuit breaker truck,isolation truck and fuse truck.
Structural characteristics:
1.This vacuum circuit breaker adopts compound insulation;it can meet air distance and creepage under normal run condition,and it effectively reduces the dimension of VCB,the overall arrangement is reasonable and simple,with aesthetic appearance.
2.The operating mechanism is adopted CD10II electro-magnetic operating mechanism or CT19n spring operating mechanism,the outlet curve has good adaptation with requirements of vacuum interrupters.It has high reliable with characteristics of long life and easy maintenance.
3.Easy pushing-in or pushing-out of panel for the truct,compulsive mechanical interlock way is adopted;meet the "Five Preventions"function;suitable for varies site and the working sites which have rigorous run condition.
Applying ambient conditions
1.Ambient temperature:-15~+40ºC.
2.The height above sea level:≤1000m(besides the special requirements).
3.Relative humidity:the average humidity of a day should be no more than 95%;the average humidity of a month should be no more than 90%.
4.Saturated vapor pressure:the average pressure of a day should be no more than 2.2kPa:the average pressure of a month should be no more than 1.8kPa.
5.Earthquake intensity:not exceed 8 degrees.
6.It should be installed in the places without fire,explosion,serious filth, chemical erosion and violent vibration.
Contact us if you need more details on Zn39-40.5. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Vacuum Circuit Breaker、High-Voltage Vacuum Circuit Breaker. If these products fail to match your need, please contact us and we would like to provide relevant information.
Truck Type Indoor High-voltage Vacuum Circuit Breaker
General Description
ZN39-40.5 type indoor HV vacuum breaker is used for many kinds of Switchgear like JYN1-35 and GBC-35.It is widely used for 40.5kV voltage systems is accordance with GB1984-2003 standards.
This series include:Vacuum circuit breaker truck,isolation truck and fuse truck.
Structural characteristics:
1.This vacuum circuit breaker adopts compound insulation;it can meet air distance and creepage under normal run condition,and it effectively reduces the dimension of VCB,the overall arrangement is reasonable and simple,with aesthetic appearance.
2.The operating mechanism is adopted CD10II electro-magnetic operating mechanism or CT19n spring operating mechanism,the outlet curve has good adaptation with requirements of vacuum interrupters.It has high reliable with characteristics of long life and easy maintenance.
3.Easy pushing-in or pushing-out of panel for the truct,compulsive mechanical interlock way is adopted;meet the "Five Preventions"function;suitable for varies site and the working sites which have rigorous run condition.
Applying ambient conditions
1.Ambient temperature:-15~+40ºC.
2.The height above sea level:≤1000m(besides the special requirements).
3.Relative humidity:the average humidity of a day should be no more than 95%;the average humidity of a month should be no more than 90%.
4.Saturated vapor pressure:the average pressure of a day should be no more than 2.2kPa:the average pressure of a month should be no more than 1.8kPa.
5.Earthquake intensity:not exceed 8 degrees.
6.It should be installed in the places without fire,explosion,serious filth, chemical erosion and violent vibration.
Contact us if you need more details on Zn39-40.5. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Vacuum Circuit Breaker、High-Voltage Vacuum Circuit Breaker. If these products fail to match your need, please contact us and we would like to provide relevant information.
Product Categories : 40.5kv-Vacuum Circuit Breaker
Other Products
Hot Products
Vs1-12 Series Indoor AC Vacuum Circuit BreakerOutdoor AC High-Voltage Disconnector SwitchLoad Break Switch Combination Fuse 12kv High Voltage Load Break SwitchTIANAN 12kv AC Metal-Clad Switchgear, High Voltage Electrical Switch Power Distribution Cabinet SwitchgearHigh Voltage Electrical Switch 12kv Indoor Sf6 Rum SwitchgearHigh Voltage 126kv Gis-Gas Insulated Switchgear (ZFW-126/T2500-40)Emergency Power Transmission/Distribution Movable Transformer Substation / 35kv~132kv Prefabricated Mobile Substation33kv Prefabricated Distribution Combined Substation Power Transmission/Supply Substation, Prefabricated Substation, Combined Substation220kv Power Transmission/Distribution Transformer Low Noise Oil Immersed Power TransformerOutdoor Hv Vacuum Circuit Breaker (ZW20-12)Indoor High Voltage Vacuum Circuit Breaker (VIB-12)Indoor High Voltage Vacuum Circuit Breaker with Lateral Operating Mechanism (VS1/R-12)Flexibar ConnectorVib-24 Indoor High Voltage Vacuum Circuit Breaker with Embedded PolesZw7-40.5 Outdoor Hv Vacuum Circuit Breaker with Central Operating MechanismVs1-12 Indoor High Voltage Vacuum Circuit Breaker