Model No.:  GW4A-40.5

Product Description

Model NO.: GW4A-40.5 Structure: Double-column Disconnector Operation: Electric Movement Mode: Horizontal Rotary Type Grounding: Single Ground Run: Turn the Horizontal Common Model: Gw4a Certification: ISO, GS, RoHS, CE, IS9001, ISO9001 Trademark: Tianan Electric Origin: Ningbo, China Type: High-voltage Installation: Outdoor High-voltage Grounding Mode: Grounding Number of Poles: Three Pole Series: Single-Stage Switching Mode: Single Throw-in Structure of Operating: Electric Brand: Tianan Specification: IEC HS Code: 8535300000 General
GW4A-40.5 D(W) isolating switches are kinds of outdoor HV electricity transmission Equipments at three phase AC frequency of 50Hz/60Hz. It is used for breaking or connecting HV lines under no loads so that the power lines can be changed and connected and the way the electricity runs is changed. In addition, it can be used to exerise safe electrical insulation for such HV electric apparatuses as bus and breaker.
This product has two insulators with horizontal center breaks. It is openable in the middle and accessible to the grounding switch on one side or two sides. The Isolating Switch adopts CS14G or CS11 manual operating mechanism ro CJ2 motor based operating mechnism to realize the tri-pole linkage. The grounding switch adopts CS14G manual operating mechanism to actualize tri-pole linkage.

Technical Data
S/N Item Unit Parameter
1 Rated voltage kV 40.5
2 Rated insulation level
 

 
3 Rated power frequency withstand voltage (1 min)
 

 
4 To earth kV 95
5 Across open breaks kV 118
6 Rated lightning impulse withstand voltage
 

 
7 To earth kV 185
8 Across open breaks kV 215
9 Rated frequency Hz 50/60
10 Rated current A 1250
2000
25000
3150
4000
11 Rated short-time withstand current kA 31.5
40
50
12 Rated peak withstand current kA 80
100
125
13 Rated duration of short circuit
Primary switch/ earthing switch
s 4/4
14 Rated terminal mechanical load
 

 
15 Horizontal -logntitudinal N 750
16 Horizontal- vertical N 500
17 Vertical force N 750
18 Creepage distance mm 1013
1256
19 Mechnical endurance times 5000
20 Motor operating mechanism
 

 
21 Model
 
CJ2
22 Motor voltage V AC 380
DC220
DC110
23 cControl circuit's voltage V AC 380
AC 220
DC220
DC110
24 Opening time and closing time s 7+/-1
25 Manual operating mechanism
 

 
26 Model
 
CS14G
27 Electromagnetic lock's voltage V AC 380
DC220
DC110

Contact us if you need more details on Disconnector. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Isolator、Isolating Switch. If these products fail to match your need, please contact us and we would like to provide relevant information.