11kV three phase Pad mounted transformer
Basic Info
Model No.: ZBW(YB)-17-10
Product Description
Model NO.: ZBW(YB)-17-10 Shell Material: Aluminum Alloy Installation: Fixed Current: AC Specification: 11kV HS Code: 8537109090 Certification: CCC, ISO9001 Voltage Level: Medium Voltage Structure: Floorstanding Trademark: TIANAN Origin: China ZBW17 (YB)-10 Series Prefabricated Substation
Total-sealed, total-insulated, safe and reliable.
Small volume and compact structure.
The cable head can be operated with the load of 200A.
Has strong over-load ability.
The body of Substation adopts special craftwork treatment and has well anticorrosion ability.
Use high burning point oil to avoid the fire.
Has beautiful appearance and assort with environment
General
ZBW17(YB)-10 Series Prefabricated (American Type) Substation is the series product in our company and it be developed by ourselves through absorb foreign technique. The Transformer, Load Switch and H.V fuse are installed in transformer's cabinet and take the insulating liquor of transformer as the insulating medium and heat-eliminating medium for whole product,it features of small volume,light weight,installation and maintenance are convenient,high safe reliability,beautiful appearance,etc.
Main purpose
ZBW17(YB)-10 Series Prefabricated Substation is used in 10/0.4kV, 50Hz power distribution system with a transformer rated capacity of 50~1600kVA. It is widely used in outdoor power supply fields such as city, residential zone, factory and mining, hotel, hospital, park, oil field, airport, wharf, railway and other temporary facilities, etc.
This product can be used not only in a close-ring-net for power distribution, but also in transformation power net for terminal power supply.
Service ambient conditions
a. Altitude above sea level: ≤1000m
b.Ambient temperature range: Max. +40ºC;
Min. -35ºC
c.Relative humidity: Daily average don't exceed 95% and monthly average value don't exceed 90%
d.Wind speed (outdoor): Not more than 35m/s
e.Installation spot: There should be no fire, explosion, badly polluted, chemical erode and strong vibration. If the condition is out of above normal service environment, the customer can consult with us to resolve it.
Type designation
Product structure
The product is made up of transformer room, H.V room and L.V room.
Performance of the transformer meets the type of SM9 or S11M.
The H.V side adopts type V or T load switch and two poles fuse to protect and use current-limiting fuse to protect circuit, the breaking capacity is big. Plug-in type fuse is used to protect the secondary side overload and short circuit of transformer.
Both load switch and fuse are installed in transformer room and make use of transformer insulation liquid as insulation medium and heat-eliminating medium.
The ingoing on H.V side adopts H.V cable plug and total insulated in the H.V room.
The outgoing on L.V side for that normal product adopts directly outgoing. It can be added L.V measuring and shunt outgoing if customer requires.
The structure of box-body is total-sealed and adopts steel plate welding, beading three side heat-eliminating. It features of strong antiseptic ability and beautiful appearance after treated by special technology.
The H.V room is isolated from L.V room and has the following components: Load switch, tap changer of transformer, H.V ingoing pin and plug-in type fuse.
The box-body equips has: oil level thermometer, oil level gauge, pressure release valve, oil drain valve and oil sample valve. L.V outgoing terminals and L.V measuring system which is required to equip by users.
Technical parameters
Table 1 Parameters of load switch
Table 2 Parameters of H.V cable plug
Table 3 Parameters of fuse
In support style current limiting fuse and plug-in type fuse are all oil immersed type.
Table 4 Technical parameters of transformer
Voltage combination
Rated voltage on H.V side: 11,10.5,10,6.3,6kV
Rated voltage on L.V side: 0.4kV
Transformer connecting mode and H.V tapping range
The connecting mode of transformer is Y,Yn0 or Dyn11. The tapping range is
±5%, ±2×2.5% or decided by users.
Contact us if you need more details on Substation. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Transformer、Switchgear. If these products fail to match your need, please contact us and we would like to provide relevant information.
Total-sealed, total-insulated, safe and reliable.
Small volume and compact structure.
The cable head can be operated with the load of 200A.
Has strong over-load ability.
The body of Substation adopts special craftwork treatment and has well anticorrosion ability.
Use high burning point oil to avoid the fire.
Has beautiful appearance and assort with environment
General
ZBW17(YB)-10 Series Prefabricated (American Type) Substation is the series product in our company and it be developed by ourselves through absorb foreign technique. The Transformer, Load Switch and H.V fuse are installed in transformer's cabinet and take the insulating liquor of transformer as the insulating medium and heat-eliminating medium for whole product,it features of small volume,light weight,installation and maintenance are convenient,high safe reliability,beautiful appearance,etc.
Main purpose
ZBW17(YB)-10 Series Prefabricated Substation is used in 10/0.4kV, 50Hz power distribution system with a transformer rated capacity of 50~1600kVA. It is widely used in outdoor power supply fields such as city, residential zone, factory and mining, hotel, hospital, park, oil field, airport, wharf, railway and other temporary facilities, etc.
This product can be used not only in a close-ring-net for power distribution, but also in transformation power net for terminal power supply.
Service ambient conditions
a. Altitude above sea level: ≤1000m
b.Ambient temperature range: Max. +40ºC;
Min. -35ºC
c.Relative humidity: Daily average don't exceed 95% and monthly average value don't exceed 90%
d.Wind speed (outdoor): Not more than 35m/s
e.Installation spot: There should be no fire, explosion, badly polluted, chemical erode and strong vibration. If the condition is out of above normal service environment, the customer can consult with us to resolve it.
Type designation
Product structure
The product is made up of transformer room, H.V room and L.V room.
Performance of the transformer meets the type of SM9 or S11M.
The H.V side adopts type V or T load switch and two poles fuse to protect and use current-limiting fuse to protect circuit, the breaking capacity is big. Plug-in type fuse is used to protect the secondary side overload and short circuit of transformer.
Both load switch and fuse are installed in transformer room and make use of transformer insulation liquid as insulation medium and heat-eliminating medium.
The ingoing on H.V side adopts H.V cable plug and total insulated in the H.V room.
The outgoing on L.V side for that normal product adopts directly outgoing. It can be added L.V measuring and shunt outgoing if customer requires.
The structure of box-body is total-sealed and adopts steel plate welding, beading three side heat-eliminating. It features of strong antiseptic ability and beautiful appearance after treated by special technology.
The H.V room is isolated from L.V room and has the following components: Load switch, tap changer of transformer, H.V ingoing pin and plug-in type fuse.
The box-body equips has: oil level thermometer, oil level gauge, pressure release valve, oil drain valve and oil sample valve. L.V outgoing terminals and L.V measuring system which is required to equip by users.
Technical parameters
Table 1 Parameters of load switch
NO. | Name | Unit | Parameters |
1 | Rated voltage | kV | 12 |
2 | Rated current | A | 630 |
3 | Rated frequency | Hz | 50 |
4 | Rated breaking current | A | 630 |
5 | Rated short-time withstand current | kA | 16/2 |
6 | Rated peak withstand current | kA | 40 |
7 | Full load breaking times | time | 20 |
8 | Mechanical endurance | time | 2000 |
9 | 1 min power frequency withstand voltage (phase to phase and phase to earth) | kV | 42 |
10 | Lightning impulse level (phase to phase and phase to earth) | kV | 75 |
Table 2 Parameters of H.V cable plug
NO. | Name | Unit | Parameters |
1 | Rated voltage | kV | 12 |
2 | Rated current | A | 200,300,630 |
3 | 1 min power frequency withstand voltage | kV | 42 |
4 | Insulation resistance | MΩ | 2000 |
5 | Contact contacting resistance | µΩ | ≤100 |
Table 3 Parameters of fuse
In support style current limiting fuse and plug-in type fuse are all oil immersed type.
Rated capacity (kVA) | Rated voltage (6kV) | Rated voltage (10kV) | ||
Current limiting fuse (A) | Model of plug-in type fuse | Current limiting fuse (A) | Model of plug-in type fuse | |
50 | 40 | C06 | 40 | C04 |
100 | 50 | C08 | 40 | C06 |
160 | 80 | C10 | 50 | C08 |
200 | 80 | C10 | 80 | C10 |
250 | 125 | C10 | 80 | C10 |
315 | 150 | C12 | 80 | C10 |
400 | 150 | C12 | 100 | C11 |
500 | 175 | C14 | 125 | C12 |
630 | 175 | C14 | 150 | C12 |
800 | 200 | C16 | 150 | C14 |
1000 | 200 | C16 | 200 | C16 |
1250 | 200 | ★ | 200 | C16 |
Table 4 Technical parameters of transformer
Rated capacity(kVA) | No-load loss (W) | Load loss (W) | Impedance voltage % | ||
S9 | S11 | S9 | S11 | ||
50 | 170 | 120 | 870 | 870 | 4 |
100 | 290 | 200 | 1500 | 1500 | |
160 | 400 | 280 | 2200 | 2200 | |
200 | 480 | 335 | 2600 | 2600 | |
250 | 560 | 390 | 3050 | 3050 | |
315 | 670 | 465 | 3650 | 3650 | |
400 | 800 | 560 | 4300 | 4300 | |
500 | 960 | 670 | 5100 | 5150 | |
630 | 1200 | 840 | 6200 | 6200 | 4.5 |
800 | 1400 | 980 | 7500 | 7500 | |
1000 | 1700 | 1190 | 10300 | 10300 | |
1250 | 1950 | 1365 | 12000 | 12000 |
Voltage combination
Rated voltage on H.V side: 11,10.5,10,6.3,6kV
Rated voltage on L.V side: 0.4kV
Transformer connecting mode and H.V tapping range
The connecting mode of transformer is Y,Yn0 or Dyn11. The tapping range is
±5%, ±2×2.5% or decided by users.
Contact us if you need more details on Substation. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Transformer、Switchgear. If these products fail to match your need, please contact us and we would like to provide relevant information.
Product Categories : Package Substation
Email to this supplier
Other Products
Hot Products
Vs1-12 Series Indoor AC Vacuum Circuit BreakerOutdoor AC High-Voltage Disconnector SwitchLoad Break Switch Combination Fuse 12kv High Voltage Load Break SwitchTIANAN 12kv AC Metal-Clad Switchgear, High Voltage Electrical Switch Power Distribution Cabinet SwitchgearHigh Voltage Electrical Switch 12kv Indoor Sf6 Rum SwitchgearHigh Voltage 126kv Gis-Gas Insulated Switchgear (ZFW-126/T2500-40)Emergency Power Transmission/Distribution Movable Transformer Substation / 35kv~132kv Prefabricated Mobile Substation33kv Prefabricated Distribution Combined Substation Power Transmission/Supply Substation, Prefabricated Substation, Combined Substation220kv Power Transmission/Distribution Transformer Low Noise Oil Immersed Power TransformerOutdoor Hv Vacuum Circuit Breaker (ZW20-12)Indoor High Voltage Vacuum Circuit Breaker (VIB-12)Indoor High Voltage Vacuum Circuit Breaker with Lateral Operating Mechanism (VS1/R-12)Flexibar ConnectorVib-24 Indoor High Voltage Vacuum Circuit Breaker with Embedded PolesZw7-40.5 Outdoor Hv Vacuum Circuit Breaker with Central Operating MechanismVs1-12 Indoor High Voltage Vacuum Circuit Breaker