High Voltage 126kv Gis-Gas Insulated Switchgear (ZFW-126/T2500-40)
Basic Info
Model No.: ZFW-126/T2500-40
Product Description
Model NO.: ZFW-126/T2500-40 Shell Material: Steel Plate Structure: Cabinet, Protection Altitude: up to 3, 000m Above Sea Level Special Conditions: Depends on The Customer Rated Short Time Continual Time: 4 S Typical Products: Zfw-126/T2500-40 Warranty: 10 Years Form: All- packaged Type Shell Protection Grade: IP56 Application Range: Substation, Building Trademark: Tianan Electric Origin: Xiangshan Zhejiang P. R China Certification: VDE, CCC, ISO9001:2000, IEC 60265-1, IEC 6227-1 Voltage Level: High Voltage Rated Voltage: 126 Kv Environment: Indoor Rated Current: 2000A Test Equipment: IEC Standard Frequency: 50 Type: Power Size: 3 Uint Operation Voltage: 126kv Brand: Tianan Specification: IEC60076-1, IEC60076-2, IEC60076-5 HS Code: 8537209000 GIS-Gas Insulated Switchgear (ZFW-126/T2500-40)
NINGBO TIANAN (GROUP) CO., LTD.
General
All requirements, which are nowadays usually specified for modern and advanced switchgear with respect to performance and reliability, are met by GIS type (ZFW-126/T2500-40) for rated voltages of up to 126 kV.
Specifications



Contact us if you need more details on 126kv Gis. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Gas Insulated Switchgear、Gis. If these products fail to match your need, please contact us and we would like to provide relevant information.
NINGBO TIANAN (GROUP) CO., LTD.
General
All requirements, which are nowadays usually specified for modern and advanced switchgear with respect to performance and reliability, are met by GIS type (ZFW-126/T2500-40) for rated voltages of up to 126 kV.
Specifications
Specification | Unit | Specified value |
Rated voltage | kV | 126 |
Rated frequency | Hz | 50 |
Rated current | A | 2000 |
Rated short time withstand current | kA | 40 |
Rated duration of short circuit | S | 4 |
Rated short time power frequency withstand voltage | kV | 230 (to earth, between poles ) |
230+73 (across open switching device) | ||
Rated lightning impulse withstand voltage (peak value) | Kv | 550 (to earth, between poles ) |
550+103 (across open switching device) | ||
Rated SF 6 gas pressure/alarm pressure value ( 20 ºC) | MPa | Circuit breaker chamber 0.6 |
Other chambers 0.5 | ||
Annual leakage rate of SF 6 | % | ≤0.5 |
Voltages of control circuit and auxiliary circuit | DC | DC 110 or 220V, AC 220V |



Contact us if you need more details on 126kv Gis. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Gas Insulated Switchgear、Gis. If these products fail to match your need, please contact us and we would like to provide relevant information.
Product Categories : SF6 HV-GIS
Email to this supplier
Other Products
Hot Products
Vs1-12 Series Indoor AC Vacuum Circuit BreakerOutdoor AC High-Voltage Disconnector SwitchLoad Break Switch Combination Fuse 12kv High Voltage Load Break SwitchTIANAN 12kv AC Metal-Clad Switchgear, High Voltage Electrical Switch Power Distribution Cabinet SwitchgearHigh Voltage Electrical Switch 12kv Indoor Sf6 Rum SwitchgearHigh Voltage 126kv Gis-Gas Insulated Switchgear (ZFW-126/T2500-40)Emergency Power Transmission/Distribution Movable Transformer Substation / 35kv~132kv Prefabricated Mobile Substation33kv Prefabricated Distribution Combined Substation Power Transmission/Supply Substation, Prefabricated Substation, Combined Substation220kv Power Transmission/Distribution Transformer Low Noise Oil Immersed Power TransformerOutdoor Hv Vacuum Circuit Breaker (ZW20-12)Indoor High Voltage Vacuum Circuit Breaker (VIB-12)Indoor High Voltage Vacuum Circuit Breaker with Lateral Operating Mechanism (VS1/R-12)Flexibar ConnectorVib-24 Indoor High Voltage Vacuum Circuit Breaker with Embedded PolesZw7-40.5 Outdoor Hv Vacuum Circuit Breaker with Central Operating MechanismVs1-12 Indoor High Voltage Vacuum Circuit Breaker