Find Distribution Substation,Power Distribution Switchgear,Metal-Clad Switchgear on Industry Directory, Reliable Manufacturer/Supplier/Factory from China.

Inquiry Basket (0)
0.6 - 69 kV YBF-40.5/0.69 Series Substation
Home > Products > All Items > Substation > 0.6 - 69 kV YBF-40.5/0.69 Series Substation

0.6 - 69 kV YBF-40.5/0.69 Series Substation

    Payment Type: L/C, T/T, D/P, Western Union
    Productivity: 50000 Sets / Year
    Place of Origin:  Xiangshan Zhejiang P. R China
    Supply Ability: 50000 Sets / Year
  • Mr. Catherine Zhou

Basic Info

Model No.:  TA-1613

Product Description

  • Model NO.: TA-1613
  • Altitude: up to 3, 000m Above Sea Level
  • Special Conditions: Depends on The Customer
  • Busbar: 3-Phase and 4-Wire
  • Typical Products: Kyn28A-12(Z)
  • Warranty: 10 Years
  • Specification: IEC60076-1, IEC60076-2, IEC60076-5
  • HS Code: 8537209000
  • Rated Insulation Voltage: 660( 1000)V
  • Environment: Outdoor
  • Rated Voltage of Main Circuit( V): AC 380( 400, 660)
  • Test Equipment: IEC Standard
  • Frequency: 50( 60)
  • Trademark: Tianan Electric
  • Origin: Xiangshan Zhejiang P. R China

KYN28A-12(Z) Metalclad Modular Switchgear Compact Switchgear
NINGBO TIANAN (GROUP) CO., LTD.

General

>>Ratings: system voltage 3.6kV, 7.2KV, 12KV, 24KV,rated current up to 4000A, 
          AC three phase 50/60HZ.
>>Application: mainly applicable in the power plant, Substation, mineral enterprise to receive and 
             Distribute power with the functions of controlling, protecting and monitoring. It also can be  
             used in places where the frequently operations are in need.
>>Standard: IEC62271-200.

Working Conditions

1. Ambient air temperature: -15°C~+40°C.
2. Altitude: ≤1000m.
3. Relative humidity : Daily average≤95%, daily averange of vapour pressure≤2.2kpa.
4. Earthquake intensity: ≤magnitude 8.
5. Applicable in the places without corrosive and flammable gas and water vapor.
6. Used in place without frequently intense vibrant.
  Note: Customized products are available.

Specifications

Item
UnitData
Rated voltagekv3.6, 7.2, 12,24KV
Rated frequencyhz50
Rated current of circuit breakerA630, 1250, 1600, 2000, 2500, 3150, 4000
Rated current of switchgearA630, 1250, 1600, 2000, 2500, 3150, 4000
Rated short-time withstands current(4s)ka16, 20, 25, 31.5, 40, 50
Rated peak withstands current (peak value)ka40, 50, 63, 80, 100, 25
Rated short-circuit breaking currentka16, 20, 25, 31.5, 40, 50
rated short-circuit making current (peak value)ka40, 50, 63, 80, 100, 25
Rated insulation level1min power frequency withstands voltagepole to pole, pole to groundkv24, 32, 42
fracture to fracturekv24, 32, 48
lightning withstands voltage(peak)pole to pole, pole to groundkv40, 60, 75
fracture to fracturekv46, 70, 85
Protection degreeEnclosure is IP4X. IP2X when CPT and CB door are open
Note: 
1. The short-circuit capacity of current Transformer is considered separately.                                                                                                          
2. Details of the parameters of ZN 63A-12 as per reference company' s sample.
 
 
   

Contact us if you need more details on Distribution Substation. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Power Distribution Switchgear、Metal-Clad Switchgear. If these products fail to match your need, please contact us and we would like to provide relevant information.